Halogen D20

Connect MP5 or MP6 to a clear local display, configured outputs and site records.

Bring the sensor and operating team together.

D20 is the Halogen controller for local readings, sensor setup and connections to your monitoring system. Its colour display brings the configured residual and supporting water-quality information to the installation.

Use it with the blue MP5 or black MP6. The guides describe two sensor Modbus connections; PMA will confirm the supported combination, firmware and power loading for your installation.

Halogen D20 controller beside a water-treatment window at golden hour

D20 controller

Display, record and connect

Local control

A 3.5-inch TFT display and menu-driven sensor configuration, with access to calibration and operating settings.

Site signals

Four configurable 0–20 mA or 4–20 mA analogue outputs, three SPDT relays and standard Modbus RTU.

Recorded information

SD-card data storage and software transfer support. Define the channels, timestamps and record retrieval workflow.

Manufacturer diagram of an MP5 flow cell connected to the D20, with inlet below and outlet above

A complete monitoring arrangement

The sensor measures the water. The controller displays and communicates the configured readings. The flow cell or mounting arrangement establishes which water reaches the sensing end.

Agree inlet and outlet routing, isolation, operating pressure, power, earthing, signal cabling and maintenance access together. The illustrated flow cell takes water in below and releases it above to let air leave.

Suitable in-pipe and immersion variants require their own installation assessment and accessories.

Plan your D20 integration

Explore D20 connections and plan how the controller will fit your monitoring system.

D20 specifications for planning

Enclosure

IP65 / NEMA 4X plastic enclosure; 160 × 160 × 101.6 mm. Choose a protected, accessible site position.

Power

The documented supply is 85–240 V AC ±10%, 50/60 Hz. Sensor power and controller loading must suit the configured system.

Interfaces

Two sensor Modbus connections, four analogue outputs, three relays and Modbus RTU. Agree the mapping before commissioning.

Environmental limits

Controller temperature limits depend on connected sensor load. Use the guide’s derating requirements rather than a single unconditional maximum.

Plan connectivity with the installation

Modbus RTU and analogue signals can connect the monitoring point to a suitable site system. Confirm addressing, scaling, status handling, loss-of-signal behaviour and who maintains the records.

Phone-app and remote access require a compatible communications arrangement. PMA will review the controller interface, network hardware and access requirements with you.

Phone displaying Halogen sensor information beside an MP5 blue sensor

Meet the Halogen family

Choose the sensor for your water chemistry, then connect it to a controller and installation that suit the site.

Halogen MP5 blue sensor with black connection cable

MP5 · free chlorine

The blue self-cleaning sensor for free-chlorine measurement, with supporting water-quality information.

Explore MP5

Halogen MP6 black sensor with black connection cable

MP6 · monochloramine

The black sensor for monochloramine and free-chlorine measurement in suitable chloraminated water.

Explore MP6

Halogen D20 controller with colour display and front controls

D20 · display and control

A colour display, configuration, analogue outputs, alarms and Modbus RTU connection for the monitoring system.

Explore D20

Downloads for your technical review

Read the manufacturer product guides for installation, operation, calibration and model-specific limits.

MP5 and D20 product guide

The supplied MP5 guide uses the MP5A model designation. PMA presents this model as MP5.

Open MP5 guide

MP6 and D20 product guide

Operating modes, reference calibration, installation requirements and technical specifications.

Open MP6 guide

Your questions, answered

Can D20 run from any 24 V DC supply?

The supplied D20 specification describes an AC mains supply. The sensors use 24 V DC. A sensor-only or alternative controller arrangement needs a separate power and integration review.

Are alarms a complete protection system?

Configure alarms around the site’s documented operating response, including signal quality and communication loss. The controller alone does not establish a complete protection function.

Looking after your world since 1971

PMA connects the measurement, installation and operating team. We help you review the application, select suitable instrumentation and plan commissioning, training and ongoing service.

Talk to the PMA team

Let’s talk about your application.

Speak to the PMA team about your instruments, reagents or service requirements. Tell us what you need, and we’ll help you find the right next step.

  • Advice for your application. Find the right instruments, sensors and chemical reagents for your process.
  • Practical service support. Discuss commissioning, calibration, maintenance or an instrument issue with our team.
  • Clear next steps. Ask a technical question or request a callback, with your site and measurements in mind.
  • An enquiry, not a mailing list. Your details are used to respond to you. You won’t be added to a marketing database.

Trusted by our clients

Prefer to speak with us?

Call 01484 843 708

You can also email [email protected].

Tell us how we can help

Share your requirements below. All fields are required.


Your enquiry goes directly to our team. Your details are used to respond to you, and you won’t be added to a marketing database. Read our privacy policy.