Halogen MP6

Black self-cleaning monitoring for monochloramine and free chlorine in suitable chloraminated water.

Keep monochloramine and free chlorine distinct.

MP6 is the black Halogen sensor for monochloramine and free-chlorine measurement in suitable chloraminated water. Its operating modes and reference calibration help the team work with the residual actually used by the process.

Review pH, ORP, conductivity and temperature alongside the disinfectant readings. These supporting measurements provide context; they do not identify every cause of a change on their own.

Halogen MP6 black sensor with black connection cable

Cleaning built into the measurement

A small motor drives a magnetically coupled impeller. Its movement circulates water at the sensing end and agitates cleaning beads across the measuring surfaces.

The beads help keep the electrodes and pH element clean while the sensor works. Electrochemical cleaning supports the mechanical action. There are no analysis reagents to replenish and no sensing membrane or electrolyte to replace.

This local movement supports measurement at low bulk-flow velocities. The sensor still needs representative water, a suitable installation and planned reference checks.

Watch the Halogen impeller and cleaning beads in motion

Built for demanding water conditions

Iron-rich water can leave heavy deposits on a sensor. Halogen’s continuous self-cleaning helps keep the measuring surfaces working, reducing routine cleaning in challenging conditions.

These photographs show an MP5 after five months in high-iron borehole water, without cleaning, recalibration or other intervention during the published trial.

These photographs show the MP5 trial and the shared self-cleaning principle.

Discuss your application
MP6

MP6 operating envelope

Model-specific values from the supplied MP6 guide. They differ from MP5 and from other Halogen sensor families.

Residual ranges

Free chlorine 0–10 ppm; monochloramine 0–5 ppm. Agree the operating mode and separate reference methods.

Measurement interval

Nominal 120-second interval in the specification. Mono-only configuration has a different cycle described in the guide.

Water chemistry

Chlorine sample pH 7.5–9.0 and conductivity 150–2,000 µS. Review suitability across your expected operating conditions.

Sample conditions

5–55°C sample temperature; published pressure limit 10 bar, subject to the mounting and installation rating.

Power and integration

24 V DC ±10%; 50 mA operating with 200 mA maximum startup. Connect through a compatible controller or reviewed PLC arrangement.

Calibration and care

Typical six-month calibration stability, with calibration checks at least every six months and care directed by the model guide.

Plan MP6 monitoring

Explore MP6 installation options and plan a monitoring point for chloraminated water.

MP6 black sensor and D20 controller mounted in a charcoal monitoring room

Connect the residual to an investigation record

Record which residual is being measured, the configured mode and the location represented. Compare each channel with the corresponding reference method rather than treating all chlorine tests as equivalent.

A change in monochloramine may need investigation alongside free chlorine, pH, temperature and separate nitrogen measurements. MP6 does not measure nitrate or nitrite.

Read the chloraminated-water guide

Downloads for your technical review

Read the manufacturer product guides for installation, operation, calibration and model-specific limits.

MP5 and D20 product guide

The supplied MP5 guide uses the MP5A model designation. PMA presents this model as MP5.

Open MP5 guide

MP6 and D20 product guide

Operating modes, reference calibration, installation requirements and technical specifications.

Open MP6 guide

Your questions, answered

Does this page describe MP-TOTAL?

No. This page describes MP6 using the supplied MP6 product guide and its model-specific free-chlorine and monochloramine ranges.

Can both residuals be calibrated?

The guide describes reference calibration for monochloramine and free chlorine, including a procedure for treated water containing both. Follow the stated mode and reference-method instructions.

How does D20 fit into the system?

D20 displays the configured sensor readings and provides local setup, records and site interfaces. PMA will confirm firmware compatibility, loading and the outputs needed by your operators.

Looking after your world since 1971

PMA connects the measurement, installation and operating team. We help you review the application, select suitable instrumentation and plan commissioning, training and ongoing service.

Talk to the PMA team

Let’s talk about your application.

Speak to the PMA team about your instruments, reagents or service requirements. Tell us what you need, and we’ll help you find the right next step.

  • Advice for your application. Find the right instruments, sensors and chemical reagents for your process.
  • Practical service support. Discuss commissioning, calibration, maintenance or an instrument issue with our team.
  • Clear next steps. Ask a technical question or request a callback, with your site and measurements in mind.
  • An enquiry, not a mailing list. Your details are used to respond to you. You won’t be added to a marketing database.

Trusted by our clients

Prefer to speak with us?

Call 01484 843 708

You can also email [email protected].

Tell us how we can help

Share your requirements below. All fields are required.


Your enquiry goes directly to our team. Your details are used to respond to you, and you won’t be added to a marketing database. Read our privacy policy.