TD-550 portable oil analyser

Portable fluorescence analysis for crude and heavier oils, with saved calibrations, recorded results and PMA support.

Practical grab-sample oil-in-water analysis

The Turner Designs TD-550 is a portable UV fluorescence analyser for discrete oil-in-water samples. Its single optical channel is suited to crude oil and other heavier oils, including diesel, lubrication oils and fuel oils.

A full-colour touchscreen supports channel and cuvette selection, calibration and extraction-ratio settings. Saved calibrations and site locations help organise repeat testing without re-entering the same information for every sample.

The instrument records a timestamp, location and result for each analysed sample. Review the history and graphs, then export data using USB or Micro SD for further analysis.

TD-550 portable oil-in-water analyser

TD-550

Build a repeatable sample workflow

Target-specific calibration

Use direct or raw calibration and retain multiple calibrations for different targets or sites. The chosen oil and preparation procedure determine how to interpret the result.

Flexible sample preparation

The manufacturer supports popular extraction solvents and TDHI’s No-Solvent Method. Select and validate the procedure for the sample matrix rather than assuming every sample can be measured untreated.

Useful recorded information

Sort stored results by date, location or calibration and graph filtered reading history. Logging makes it easier to compare site checks and investigate changes over time.

Technical details for your specification

Published manufacturer specifications are a starting point. Confirm the supplied configuration, target sample and installation conditions with PMA.

Measurement

UV fluorescence; a single optical channel suited to crude and heavier oils.

Target hydrocarbons

Crude oil, diesel, lubrication oils and fuel oils. Confirm response and calibration for your specific product or mixture.

Detection range

5 ppb–5000 ppm, dependent on target oil. This is a published range, not a universal detection limit for every sample matrix.

Power

External 90–240 VAC power supply; published battery operation of 6–8 hours. Actual field planning should include charging and the intended use.

Data and display

USB and Micro SD output. Display units include ppm, ppb, mg/L, µg/L and raw signal.

Calibration and records

Direct and raw calibration; multiple calibrations and site locations; timestamped sample results and graphing. Manufacturer brochure lists CE approval.

Applications for portable TD-550 analysis

Use a defined sampling and preparation method, with a calibration relevant to the oil being assessed.

Produced water and wastewater

Check discrete samples when assessing treatment performance or investigating a changing oil response. Match the reporting basis to the method required for your process.

Explore application

Cooling water and condensate

Investigate suspected contamination in cooling circuits or condensate samples. Representative collection and controlled preparation are essential at low concentrations.

Explore application

Crude and heavier-oil investigations

Use a defined target-oil calibration for crude, diesel, fuel or lubrication-oil samples. Discuss mixed or changing oil compositions with PMA.

Stormwater and soil extracts

The manufacturer lists stormwater and oil-in-soil analysis. Soil work requires suitable extraction and reporting calculations; the analyser is not a direct in-ground soil sensor.

From sample collection to a useful result

Start with the decision you need to make and the reference method, if one is specified. Establish representative sample collection, preparation, blanks and calibration checks for your target and water matrix.

The manufacturer states that results can be correlated to official laboratory methods such as USEPA 1664A and ISO 9377-1. Demonstrating that correlation requires a validated procedure and representative comparison samples; it is not an automatic equivalence for every oil or application.

If the target includes lighter fuels, BTEX or gas condensates, review the TD-560’s second optical channel. TD-550 suitability should be assessed against the actual oil and sample conditions.

PMA team member preparing equipment for a customer visit

Resources and your next step

Manufacturer brochure

Review the measurement principle, published specifications and available features for this product.

View the brochure

Application review

Send your sample conditions and operational objective so PMA can review the right configuration.

Request a quotation

Read PMA’s existing solvent-free extraction article. Read the TD-550 and TD-560 comparison.

Questions to help you choose

How does TD-550 measure oil in water?

It measures a fluorescence response from a prepared sample using the selected optical channel. Calibration relates that response to a defined target oil or reporting basis.

Can every sample be tested without solvent?

No-solvent analysis is a supported option, but its suitability depends on the oil, matrix and required result. Agree the procedure and validate it before routine testing.

How is TD-550 different from TD-560?

TD-550 uses one optical channel for crude and heavier oils. TD-560 includes that channel and adds another for lighter hydrocarbons.

Explore the Turner Designs range

TD-560 dual-channel analyser

Portable analysis with a second optical channel for lighter hydrocarbons as well as the oils measured by the TD-550.

Explore TD-560

TD-120 online oil monitor

Continuous UV fluorescence measurement for oil contamination, process protection and treatment monitoring.

Explore TD-120

CF-200 algae bloom monitor

Continuous chlorophyll-A fluorescence measurement for algae-bloom warning and water-intake protection.

Explore CF-200

The Turner Designs range

Compare portable oil analysis, continuous oil monitoring and chlorophyll-A measurement with PMA.

Compare the range

Let’s talk about your application.

Speak to the PMA team about your instruments, reagents or service requirements. Tell us what you need, and we’ll help you find the right next step.

  • Advice for your application. Find the right instruments, sensors and chemical reagents for your process.
  • Practical service support. Discuss commissioning, calibration, maintenance or an instrument issue with our team.
  • Clear next steps. Ask a technical question or request a callback, with your site and measurements in mind.
  • An enquiry, not a mailing list. Your details are used to respond to you. You won’t be added to a marketing database.

Prefer to speak with us?

Call 01484 843 708

You can also email [email protected].

Tell us how we can help

Share your requirements below. All fields are required.


Your enquiry goes directly to our team. Your details are used to respond to you, and you won’t be added to a marketing database. Read our privacy policy.